J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Installation Type: Needle Terminal
Sensing Type: Thermocouple
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (18)
  • J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
  • J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
  • J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
  • J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
Find Similar Products
  • Overview
  • Specification
  • Product Description
  • Packing & Delivery
  • After Sales Service
Overview

Basic Info.

Model NO.
J typer Hot Runner Plastic Head Thermocouple
Contact
Contactless
Output Signal Type
Digital Type
Production Process
Normal Wirewound
Material
Plastic
Measuring Medium
Temperature
IP Rating
IP20
Certification
CE
Customized
Accept Customization
Temperature Range
0~200℃
Type
Electric Water Heater Parts
Theory
Temperature Sensor
Index Number
J Type
Armor Wire Diameter
1.0mm/1.5mm
Probe Length
50/100/150/200/250/300mm
Cable Length
1m/1.5m/2m(Accept Customization)
Transport Package
Plastic and Carton
Specification
SUS, resistance wire
Trademark
LUJINXUN
Origin
China
HS Code
84779000
Production Capacity
5000PCS One Week Can Supply

Product Description

J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
Specification
Type
Electric Water Heater Parts
Theory
Temperature Sensor
Index Number
Type J
Temperature Measurement Range
0~200℃
Armor Wire Diameter
1.0mm/1.5mm
Cable Length
1M/1.5M/2M
Probe Length
50/100/150/200/250/300mm
Can be Customized
Yes
Specification Size
J-type heat flux long probe thermocouple probe armored temperature sensing wire with high precision can be bent and high temperature resistant.
Cable 1M 1.0x50mm 1.0x100mm 1.0x150mm 1.0x200mm 1.0x250mm 1.0x300mm 
Cable 1M 1.5x50mm 1.5x100mm 1.5x150mm 1.5x200mm 1.5x250mm 1.5x300mm 
Cable 1.5M 1.0x100mm 1.0x150mm 1.0x200mm 
Cable 1.5M 1.5x100mm 1.5x150mm 1.5x200mm 
Cable 2M 1.0x100mm 1.0x150mm 
Cable 2M 1.5x100mm 1.5x150mm
(Accept Customization)
If you want other type probe length,wire length or probe diameter, please check our store or connect Customer Service.
Product Description
Product Introduction
J-type long probe thermocouple is a special sensor designed based on the characteristics of J-type (iron-copper-nickel alloy) thermocouple, and its core feature lies in the adaptability of long probe structure to hot runner scene. 
It adopts the design of extended probe, which can go deep into special spaces such as long and narrow hot runner and deep cavity of die, and directly contact the core area of measured medium.
Product Advantage
1.Based on the inherent characteristics of J-type thermocouple (iron-copper-nickel alloy), the long probe thermocouple can stably measure the temperature range of 0-200℃, especially in the middle and low temperature range, showing excellent linearity and sensitivity, and can accurately capture the subtle temperature fluctuations in the hot runner.
2.By adopting the extended probe structure, it can go deep into the special space of the hot runner system, such as the narrow runner and the inside of the pipeline, and directly contact the core area of the measured medium, so as to avoid the deviation of the measuring point caused by the insufficient probe length and ensure that the temperature data reflects the real working conditions.
3.Support a variety of installation methods (such as thread fixing and flange connection), and customize the probe length and fixed interface according to the hot runner structure, without large-scale transformation of the equipment structure.
4.J-type thermocouple with long hot runner probe has become an ideal choice for temperature monitoring of hot runner system by virtue of its combined advantages of "long distance+accurate measurement+durability and economy", especially in industries that rely on stable melt temperature control, such as injection molding, rubber and packaging, which can effectively improve product quality stability and production efficiency.
Product Operate Guide
1. Selection of Thermocouple Type
Choose the appropriate thermocouple type (e.g., K, J, T, S) based on the temperature range of your application. 
2. Installation Preparation
Ensure the thermocouple probe is clean and free of damage (e.g., cracks in the sheath). For accurate readings, position the sensing junction (the tip) directly in the area where temperature needs to be measured—avoid contact with non-target surfaces like walls or pipes, unless measuring surface temperatures.
3. Electrical Connection
Connect the thermocouple wires to a compatible temperature controller, data logger, or meter. Match the positive (usually red) and negative (often blue) leads to the corresponding terminals on the device. Use extension wires of the same thermocouple type to avoid measurement errors from temperature gradients in the connection lines.
4. Operation
Power on the measurement device and allow the thermocouple to stabilize—response time varies by design, but most reach steady readings within seconds. Monitor the display for real-time temperature data. Avoid exposing the thermocouple to excessive vibration, mechanical stress, or corrosive environments beyond its rated limits.
5. Maintenance and Storage
After use, inspect the thermocouple for wear, corrosion, or bending. Clean the probe with a soft cloth or appropriate solvent (avoid abrasive materials). Store in a dry, cool place, coiled loosely to prevent wire damage. Replace the thermocouple if readings become inconsistent or the sheath is compromised.
Follow these steps to ensure reliable, accurate temperature measurements with your thermocouple. Always refer to the manufacturer's specifications for model-specific guidelines.
J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
Product Uses
J-type thermocouple with long heat flux probe is especially suitable for the scene that needs to go deep into narrow space and directly monitor the surface temperature of high-temperature fluid or solid because of its long-distance measurement ability, medium-high temperature adaptability, high cost performance and mechanical impact resistance.
1.Hot runner system of injection molding and mold
2.Extruder and plastic processing equipment
3.Temperature measurement of industrial furnaces and pipelines
4.Food and pharmaceutical processing equipment
5.Engine and power equipment testing
 
The core value of J-type thermocouple with long heat flux probe lies in the combination ability of "long distance and accurate temperature measurement", which is especially suitable for long and narrow space, medium and high temperature environment and scenes requiring direct contact with the measured medium. It has become a key sensor to improve production accuracy and equipment reliability in industries such as injection molding, extrusion, furnaces and food processing.
J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
Packing & Delivery
Fast Shipping
Please provide full name,correct post code and valid phone number to avoid any delay of delivery.
 We guarantee to ship out within 3-5 working days after payment confirmed.
 If there is any unexpected situation,we will contact you as soon as possible.
After Sales Service
J Type Hot Runner Plastic Head Thermocouple Temperature Sensing Line
About Feedback
If you are satisfied with our product and service,Please leave us positive feedback and 5 stars review!
If you are unhappy with service or any other problem,Please contact us before leaving feedback,and we will resolve the issue immediately.
Customer's satisfaction is our goal!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now